• That the electrical socket that you wish to use has the same voltage as is given
on the unit's specification plate (220-240V~50Hz)
• That no other devices are connected to the same socket
If this has all been checked, you can insert the plug into the socket.
Switch the device on with the 'power' button.
Cooling function
➢ Press the 'Mode' button until the 'Cool' light is shown on the display.
➢ The display shows 25°C.
➢ Set the required temperature with the Temp ▲ / Temp▼ button. The display
shows the configured temperature. The temperature can be set between 16 and
31°C.
➢ Press the 'Speed' button to set the ventilator speed at low, medium or high.
➢ Observe an interval of at least 3 minutes between every on/off.
Dehumidification function
➢ Press the 'Mode' button until the 'Dehum' light is shown on the display.
➢ Check if the water discharge is connected correctly.
➢ The display automatically shows 2°C below the room temperature.
➢ The temperature cannot be changed.
➢ The ventilator speed is automatically set to low.
➢ Observe an interval of at least 3 minutes between every on/off.
Ventilation function
➢ Press the 'Mode' button until the 'Fan' light is shown on the display.
➢ The display shows 25°C.
➢ Set the power to low, medium or high with the 'Speed' button.
➢ The temperature cannot be changed.
Timerfunction
Automatic start:
➢ First set at which temperature and in which mode (cooling, dehumidifying or
ventilating) you want the air conditioner to start.
➢ Switch off the air conditioner using the <On/Off> button. Now the air conditioner
is in the stand-by position.
➢ Press the <Timer> button.
➢ Using the <Up> and <Down> buttons, set the number of hours after which the
air conditioner has to start (1-24 hours).
➢ Press the <Timer> button once again. The displays of the air conditioner and the
remote control show the set number of hours.
The air conditioner will automatically start with the entered settings after the
lapsing of the set number of hours.
Automatic stop:
➢ Press the <Timer> button while the air conditioner is operating.
49