Installation

2.3 Mains Plug Connection

EN
Never use the mains cable of the machine without a plug for your safety.
Protect the equipment with slow blow fuse appropriate for the system and with an
• Use the appropriate ground cable for your power supply. Push the chassis connector into the connector on the
emergency switch that will quickly shut off the incoming electricity in an emergency.
power supply and snap it in, make sure the connection is tight.
• Electrical connection works should be carried out by a qualified electrician in accordance with local and
national regulations.

2.4 Connection to Mains

When plugging the power plug into the outlet, make sure that the power switch is set to "0".
• Before connecting the machine to the mains, check the 3 phases with a voltmeter. After making sure that each
phase is correct, insert the plug into the socket.
• Start the machine by using the On/Off switch.
• The machine is ready to start after the MW symbol appears on the screen. (ID 65 PX)
• Turn the machine off by turning the switch back to the "0" position.

2.5 Connections for Plasma Cutting

Be careful during the cutting process and wear appropriate protective clothing and gloves.
• If the gas source is in the workshop or gas cylinder, a gas regulator should be used and this regulator should be

2.5.1 Gas Connections

able to supply gas to the air inlet on the machine.
• If a gas cylinder is used, secure the gas cylinder to prevent it from tipping over.
• In order to work safely and achieve the best results, use a regulator that complies with standards and make sure
the gas supply quality is up to the standards. Gas supply quality will affect cutting performance and
consumption quality.
• Protect the gas line from contaminants such as oil, dust, etc.
• Keep the gas cylinder valve open for a while to allow possible sediment and particles to be discharged.
• Connect the gas regulator to the gas cylinder, make sure that the screw thread on the gas outlet of the gas
cylinder and the nut of the regulator overlap.
• Connect one end of the tube hose to the gas regulator and the other end to the gas inlet at the back of the
machine and open the gas cylinder valve.
• Adjust the gas flow with the pressure regulating valve.
• Make sure there are no leaks in the connections.
• The air filter may be damaged if the upper limit of the inlet gas pressure is exceeded.
Gas Source
Recommended gas inlet flow rate / pressure
• Insert the plug of the ground clamp cable into the grounding socket on the machine and tighten it by turning it

2.5.2 Grounding Pliers Connections

to the right. Make sure the connection is made.
• To improve cutting quality, firmly attach the ground clamp to the work piece as close as possible to the area to
be cut.
USER MANUAL
Clean, dry, oil-free air or nitrogen
Cutting : 185 l/min at 5.5 bar.
Gouging : 208 l/min at 4.6 bar.
ID 65 PX / ID 65 P