3. Run the system up and at the same time turn the UP limit switch screw in the "
system stops. If the system goes beyond the UP limit switch position required without stopping, proceed
as follows:
A) stop the system
B) run the system down, and without touching the UP limit switch, take the blind down to half way
C) run the system up and at the same time turn the UP limit switch screw in the "
the system stops. If necessary repeat the operation from point A
4. Once the UP limit is reached, the system stops. At this point, if the position needs to be corrected, then:
• to shorten the travel of the blind:
D) run the system down so the blind drops by a few cms
E) turn the UP limit switch screw a few turns in the "
F) run the system up and see where the system stops. If necessary repeat the operation from point D
• to lengthen the travel:
G) with the system stopped at the UP limit switch and not supplied with power, turn the UP limit
screw a few turns in the "
H) run the system up and see where the system stops. If necessary repeat the operation from point G
5. Once the UP limit switch has been corrected, check that the system works properly by moving the
system in both directions until it stops at the limit switches.
FAULT
The system does not move
The system does not stop
at the correct position
Voltage: 24 VDC
Current: 0,3 A
Power: 7,2 W
Torque: 2 x 0,4 Nm (Softbox 437 - Qbox 457 – Plì 353/4)
Revolutions: 42 RPM (Softbox 437 - Qbox 457 – Plì 353/4)
Limit switch capacity: 60 turns
Length of power lead: 3 m 
8
+
" direction

Troubleshooting

POSSIBLE CAUSE
Limit stops incorrectly set
Incorrect wiring
No electrical power
Faulty motor unit.
Limit stops incorrectly set
Obstructions in the curtain
work space

Technical Characteristics

4
Z237-1rB
-
" direction
REMEDY
Set the limit stops
Check and correct the wiring by following
the instructions in this manual
Restore electrical power
Request replacement of the motor unit
Set the limit stops
Remove obstructions
/
2 x 0,7 Nm (Qbox 457)
/
25 RPM (Qbox 457)
-