Download Print deze pagina

Barbecook SPRING 3002 Handleiding pagina 11

Advertenties

5.
Set the control knob of one burner to HIGH.
Always light one main burner to start with. Never light all
main burners at the same time.
6.
lf the burner does not light within 5 seconds, set its control
knob to OFF, close the gas supply and wait 5 minutes. This
allows any accumulated gas to escape.
7.
Retry lighting the burner. lf it still does not light, refer to "14
Troubleshooting" to determine the cause of the problem.
8.
Once one burner is lit, light the other burners by setting their
control knobs to HIGH.
9.4
Proceed as follows:
1.
Close the gas supply.
2.
Set the control knobs of the burners to OFF.
By closing the gas supply first, you make sure there is no
gas left in the appliance.
9.5 Relighting the burners
lf a burner goes out while in use, proceed as follows:
1.
Open the lid and close the gas supply.
2.
Set all control knobs to OFF and wait 5 minutes. This allows
any accumulated gas to escape.
3.
Relight the burner(s).
9.6 Checking the flames
Each time you light a burner, you have to check its flames. A
perfect flame is almost completely blue, with some yellow at the
top. Sporadic yellow flames are normal and not harmful.
lf there is something wrong with the flames, do one of the
following to solve the problem:
If the flames are...
Low and entirely yellow
Higher than the bowl
Do the following...
1.
Immediately close the gas
supply and set all control
knobs to OFF.
2.
Refer to "Troubleshooting"
to determine the cause of
the problem. Most likely, the
venturis are blocked.
1.
Immediately close the gas
supply and set all control
knobs to OFF.
2.
Wait 5 minutes to allow any
accumulated gas to escape.
3.
Relight the burner(s).
4.
If the problem persists, refer to
"Troubleshooting" to determine
the cause of the problem.
www.barbecook.com