installation
(continued)
The discharge stump has a diameter of 150 mm. It is best if
the discharge pipe also has this diameter.
A reducing piece (150 mm to 125 mm) is supplied w ith the
appliance for connection to a 125 mm discharge pipe.
ATAG supplies accessories for discharge ducts for extractor
hoods. You w ill find an overview of the range w ith the
appropriate type numbers in the price list.
assembly
building-in dimensions w all hood
800-1000
235
130
410
530
min. 650
GB 10
¿150/125
240
755
900
W G3/4/8X
assembly
(continued)
installation w all hood
The most important dimensions are show n on the previous
page. You can set the height of the telescopic pipe. Take the
allow able tolerances into account.
Position the discharge and the electrical connection in such
a w ay that it w ill be easy to hook up the hood.
marking out and fitting fixing materials
Draw a vertical centre line on the w all (centre of the
extractor hood).
Place the fastening clip against the w all so that it rests
against the ceiling. The arrow on the flanged rim indicates
the middle of the cooker hood. M ark the attachment holes to
be drilled.
Drill the holes (ø 8 mm).
Put the plugs into the w all and fix the fixing bracket to the
w all w ith the screw s supplied (5 x 50 mm).
marking out and fitting motor module
M ark the position of the underside of the hood on the w all
(bear in mind the minimum distance to the hob). M ark the
(vertical) centre line.
Fold or cut the template depending on type and mark the
upper fixing holes.
20
Drill the fixing holes (2 x ø 10 mm).
Fix the plugs. Screw tw o nuts onto the threaded ends in the
opposite direction. Screw the threaded ends into the w all
leaving 20 mm projecting (see illustration).
Remove the nuts.
GB 11