EN
5. Overload Protection:
In the event of a power loss, to protect the compressor there is a
3-minute delay until the compressor restarting.
DRAINAGE
Self- evaporating system:
The self-evaporating system uses the collected water to cool the
condenser coils for better efficient performance. It is no need to empty
the drainage tank in cooling operation except in heating operation,
drying operation and high humidity conditions. The condensate water
evaporates at the condenser and evacuated through the exhaust hose.
For continuous operation or unattended operating in drying and
heating operation, please connect the attached drain hose to the unit.
Condensate water can be automatically flow into a bucket or drain by
gravity.
- Switch off the unit before operating.
- Remove the plug of the water outlet opening, and keep it in safe area.
- Securely and properly connect the drain hose and make sure it is not
kinked and clear of obstruction.
- Place the outlet of hose over a drain or bucket and ensure that water
could freely flow out of the unit.
- Do not submerge the end of hose into water; otherwise it can cause
"Air Lock" in the hose.
To avoid water spillage:
- As the negative pressure of condensate drain pan is large, tilt the
drain hose downward toward the floor. It is appropriate that the degree
of inclination should exceed 20 degrees.
- Straighten the hose to avoid a trap existing in the hose.
Portable Airconditioner - English manual
21