E. Sleep mode:
The sleep mode can be activated when in cool mode.
In cool mode :
After 1 hour the preset temperature is increased by 1ºC, after another
hour the preset temperature will again be increased by 1ºC.
In heat mode (Optional for Heating Function Unit only) :
After 1 hour the preset temperature is decreased by 1 ºC, after another
hour the preset temperature will again be decreased by 1 ºC.
Then the temperature is kept constant for 10 hours. And all the
indicators dim to dark. The fan speed may switch over to low speed for
silent operating and cannot be selected.
3. Timer settings (1hour-24hours):
The timer has two ways of operation
To turn off (When power on)
1. Press Timer key to turn on the timer function.
2. Press ADD/MINUS repeatedly to set the delay OFF time.
To turn off (When power off)
1. Press Timer key to turn on the timer function.
2. Press ADD/MINUS repeatedly to set the delay ON time.
Cancel timer
1. Press ADD/MINUES repeatedly until the LED shows '00'.
Note: when press POWER will also exit the timer setting.
4. Automatic Defrost:
At low room temperatures, frost may buildup at the evaporator during
operation. The unit will automatically start defrosting and the POWER
LED blinking. The defrost control sequence is as follows:
A.When the unit operates in the cooling operation, drying operation,
the ambient temperature sensor senses the evaporator coil temperature
is below -1°C, after the compressor will stop operating for 10 minutes
or the coil temperature up to 7ºC, the unit restart to cool operating
mode.
B.When the unit operates in the drying operation, once the coil
temperature sensor senses the temperature of the evaporator is below
40ºC and the differential temperature between coil temperature and
room temperature is below 19ºC after the compressor operation
for 20minutes, the unit start defrosting for 5 minutes and the power
indicator blinking.
Portable Airconditioner - English manual