x 2
add. start
Add. 2ch
erase 64
language
autoset
Control unit
software version
stat
vers
No total manoeuvres
(in hundreds)
n. cycles
No radio control
devices memorised
n. Remotes
List of last 30 errors
err
0---
password
20 -
THALIA
https://alborzsanat.com
ACCESS MENUS Fig. 1
hidden butt
release
hidden butt
release
DIAGNOSTICS
CODE
START E external start input activated
STRE
START I internal start input activated
STRI
OPEN input activated
OPEN
CLOSE input activated
CLS
PED pedestrian input activated
PED
TIMER input activated
TI E
STOP input activated
STOP
PHOT photocell input activated
PHOT
PHOT OP opening photocell input activated
PHOP
PHOT CL closing photocell input activated
PHCL
BAR safety edge input activated
BAR
SWC1 motor 1 closing limit switch input activated
SWC1
SWO1 motor 1 opening limit switch input activated
SWO1
SWC2 motor 2 closing limit switch input activated
SWC2
SWO2 motor 2 opening limit switch input activated
SWO2
The board is standing by to perform a complete
opening-closing cycle uninterrupted by intermediate
SET
stops in order to acquire the torque required for move-
bft . . .
ment. WARNING! Obstacle detection not active.
+/-
Photocell test failed
ER01
Safety edge test failed
ER02
0000
+/-
Opening photocell test failed
ER03
Closing photocell test failed
ER04
Board hardware test error
00
ER1x*
+/-
Encoder error
ER2x*
01.33
Reverse due to obstacle - Amperostop
ER3x*
02.01
Thermal cutout
ER4x*
Communication error with remote devices
ER5x*
........
Running off battery
ER61
30.15
Limit switch error
ERFx*
+/-
* X = 0,1,...,9,A,B,C,D,E,F
10--
See PARAMETERS
MENU
See LOGIC MENU
desired button
desired button
See RADIO MENU
DIAGNOSTICS and WARNINGS
DESCRIPTION
150-
Scroll up
Scroll down
Con rm
Switch on display
Exit Menù
35. 4 0
Instantaneous force motor 2
Instantaneous force motor 1
NOTES
Check photocell connection and/or logic
settings
Check safety edge connection and/or logic
settings
Check photocell connection and/or parameter/
logic setting
Check photocell connection and/or parameter/
logic setting
- Check connections to motor
- Hardware problems with board (contact technical
assistance)
- Motor power or encoder signal cables inverted/
disconnected.
- Actuator movement is too slow or stopped with
respect to programmed operation.
Check for obstacles in path
Allow automated device to cool
Check connection with serial-connected accessory
devices and/or expansion boards
--
Check limit switch connections
1520
prg