CAUTION
Damage to property due to incorrect handling! Incorrect handling can result in damage to the pressing
tool and/or the pressing rings.
▶ Before starting work, make sure that the pressing rings are dust-free.
▶ Before starting work, lubricate the pressing rings and - if present - the rolling actuator with lubricant and
corrosion-inhibiting spray (#308976).
▶ Comply with the original operating instructions of the manufacturer.
In order to achieve a tight, durable crimped / pressed joint, it is essential that the crimping / pressing
jaws reach the fully closed position, thus indicating completion of the crimping / pressing operation.
If the crimping / pressing operation is ended prematurely, the fitting must be removed or, if possible,
recrimped / repressed.
In cold weather the hydraulic oil can thicken and slow the crimping / pressing operation. Perform 5 to
10 empty crimping / pressing operations to heat up the crimping / pressing tool.
1. Insert the crimping / pressing jaws.
2. Squeeze the legs of the pressing jaws together.
▶ The pressing jaw opens.
3. Enclose the fitting to be installed in the pressing jaw.
4. Press and hold down the control switch until the piston retracts.
▶ The pressing operation is completed successfully.
7
Care and maintenance
WARNING
Risk of injury if service not performed !
▶ Servicing is required after 15,000 cycles or 1 year and must be performed by an authorized Hilti Service
Center. Neglecting regular servicing can lead to serious safety risks for the operator and/or to faulty
pressings.
WARNING
Risk of injury with battery inserted !
▶ Always remove the battery before carrying out care and maintenance tasks!
Care of the product
•
Carefully remove stubborn dirt.
•
Carefully clean the air vents, if present, with a dry, soft brush.
•
Use only a slightly damp cloth to clean the housing. Do not use cleaning agents containing silicone as
these can attack the plastic parts.
•
Use a dry, clean cloth to clean the contacts of the product.
Care of the Liion batteries
•
Never use a battery with clogged air vents. Clean the air vents carefully using a dry, soft brush.
•
Avoid unnecessary exposure of the battery to dust and dirt. Never expose the battery to high levels of
moisture (e.g. by being dipped in water or left in the rain).
If a battery has been soaked by moisture, treat it as a damaged battery. Isolate it in a non-flammable
container and consult Hilti Service.
•
Keep the battery free of extraneous oil and grease. Do not permit dust or dirt to accumulate unnecessarily
on the battery. Clean the battery with a dry, soft brush or a clean, dry cloth. Do not use cleaning agents
containing silicone as these can attack the plastic parts.
Do not touch the contacts of the battery and do not remove the factory-applied grease from the contacts.
•
Use only a slightly damp cloth to clean the housing. Do not use cleaning agents containing silicone as
these can attack the plastic parts.
22
English
20
2188464