Operating instructions SATAjet 4000 B RP/HVLP (DIGITAL)
The painter is not exposed to vibrations while using the spray gun. Repul-
sive forces are minimal.
6.4. Use In Explosive Areas
The product labelling must be adhered to.
6.4.1 General
The spray gun is approved for the use / storage in explosive areas of Ex-
Zone 1 and 2.
• The following applications and operations lead to the loss
of the explosion protection and are, therefore, prohibited:
• Use of the spray gun in explosive areas belonging to ex-zone 0!
• Do not use solvents and cleaning agents based on halogenised
hydrocarbons! Chemical reaction which may occur when using these
substances may be explosive!
6.4.2 Additional Information on the Electronic
Pressure Gauge
The electronic pressure gauge has passed a design examination. It has
been developed, constructed and manufactured in accordance with the
EU Directive 2014/34/EU. It has been classified according to Ex ia IICT4
Ga or Ex ia IICT4 Gb It may be used and stored in the explosive zones
1 and 2 up to 60°C ambient temperature. Inspection authority: KEMA
05 ATEX 1090 X. Additional certifications: FM Global IS CL I DIV 1 GPS
ABCD T4 Ta = 60°C, IS CL I DIV 1 ZN 0 AEx ia IIC T4 Ta = 60°C
and CSA IS CLI I DIV 1, GP A, B, C, D T4, Ex ia IIC T4 Gb, CL I ZN 1 A/
Ex ia IIC T4 Gb Tamax = 60°C, CSA_05CA1692762.
The following applications and operations lead to the loss of
the explosion protection and are, therefore, prohibited:
• Battery replacement in explosive areas!
• Removal of the front cover of the pressure display!
Danger! Risk of explosion!
Danger! Risk of explosion!