Behaviour in the event of a power cut: This parameter is used to select the behaviour of the automated system when mains power
Without battery kit: If mains power fails, the automated system remains in the position it is in that moment.
0
Without battery kit: If mains power fails, the automated system remains in the position it is in that moment.
1
With battery kit: In the event of a mains power failure, the automated system continues its normal operation. At
0
With battery kit: If mains power fails, the control unit automatically commands an opening movement of the
1
Immediate closure: If this function is activated, when the automated system is open in pause and the photocells detect a transit, the pho-
tocells command an automatic re-closure of the automated system without waiting for the pause time to elapse
0
Immediate closure disabled
o
1
Immediate closure activated
Immediate closure/Timer: This function is used to select the immediate re-closure of the automated system or stop with the OPEN/CLO-
SE input
Immediate closure: When the automated system is open in pause, an impulse of the OPEN/CLOSE command
0
P
Timer function: When the automated system is open in pause, an impulse of the OPEN/CLOSE input causes
1
Fototest: If this function is activated, the control unit performs a check of the correct operation of the connected safety devices before
each closing movement
0
Fototest function disabled
S
1
Fototest function activated
Safety devices: This function is used to select the type of activation of the connected safety devices: active only during the closing move-
ment of the automated system or active during opening, too.
0
Safety devices active only during the closing movement of the automated system
y
1
Safety devices active during the closing and opening phase of the automated system
is cut.
When the mains power is present again, the control unit automatically commands, after
two seconds, a beam re-closure and prepares for normal operation. The first opening
movement performed by the automated system occurs at decelerated speed.
When mains power is present again, send an OPEN or OPEN/CLOSE pulse to resume
normal operation of the automated system. When mains power is present again, the
first two (closing and opening) movements performed by the automated system occur at
decelerated speed. The automated system resumes normal operation only after having
carried out an opening movement at decelerated speed.
the end of every opening movement, the flashing lamp (external flashing lamp or the luminous
strip on the upright sides) flashes twice in succession with a 3-second interval for a max.
time of 15 seconds indicating thus that the automated system is only powered by batteries.
The battery charge level is constantly monitored by the control unit: when the batteries are
almost flat, the control unit stops the beam in open position. It resumes normal operation
when mains power is present again. When the batteries are completely flat, the automated
system behaves as if buffer batteries were not connected.
automated system and stops the rod in opening position disabling all commands. When
the mains power is present again, if automatic re-closure was selected, the control unit
automatically commands the beam re-closure and sets for normal operation. If the automatic
re-closure was not selected, when the mains power is present again, the automated system
waits for a CLOSE or OPEN/CLOSE command to resume normal operation. When batteries
are flat, the automated system behaves as buffer batteries have not been connected.
input
.
b
causes the automated system to start the closing phase without waiting for the pause
time to elapse.
the control unit to resume the pause time count. If the OPEN/CLOSE command is held down,
the pause time count stops. When the command is released, the control unit resumes the
pause time count and then closes.
.
c
Description
.
a