Download Inhoudsopgave Inhoud Print deze pagina

General Characteristics; Technical Specifications; Preparations; Board Layout - FAAC E607 Handleiding

Inhoudsopgave

Advertenties

Thank you for choosing our product. FAAC is sure that it will give you all the performances you are looking for. All our products are the
result of a long experience in the field of the automated systems.
The E607 control unit was developed and realized to control electro-mechanical barriers for vehicle access control.
Thanks to the innovative switching supply system, the control unit is able to automatically adapt to different input voltages (230 V~ o 115
V~) keeping unchanged the outputs value on both the motor and the accessories, without suffering any variations.
The very simple programming of the main functions enables reduced installation times, while a series of built-in LEDs provides for a rapid
and safe diagnostics on the status of safety devices and control devices connected to the control unit.
Thanks to the encoder management, this control unit, if correctly installed and adjusted, enables you to reduce the number of devices
necessary for the realization of an installation in compliance with current safety standards.
To ensure people's safety, all warning and instructions in this booklet must be carefully observed.
Incorrect installation or incorrect use of the product could cause serious harm to people.
Carefully read this manual before installing the product.
Store these instructions for future references.
Power supply voltage and frequency
Absorbed power
Max. power at thrust
Accessories max. load
Operating ambient temperature
Protective fuses
Function logics
Opening/Closing max. time
Pause time
Encoder sensitivity
Terminal board inputs
Rapid connector
Terminal board outputs
Board dimensions
Make sure that an adequate differential switch is installed upstream of the system as specified by current safety standards.
On the power supply mains install a thermal breaker with omnipolar switching.
Make sure that an adequate earthing system is available.
To lay cables, use adequate rigid and/or flexible tubes.
Always separate the 230/115 V~ power cables from low voltage connections, using separate sheaths to avoid possible interference.
With reference to figure 1:
Pos.
CN1
Power supply terminal board
CN2
Motor and travel-limit terminal board
CN3
Light outputs terminal board
CN4
Inputs terminal board
CN5
Battery terminal board
JP1
Not used
JP2
Radio module rapid coupling
JP3
Encoder connection Molex
F1
Power supply 230/115V~ circuit fuse
F5
Motor power supply circuit fuse
P1
Parameter selection push-button
P2
Parameter adjustment push-button
RESET Reset push-button

1. GENERAL CHARACTERISTICS

2. TECHNICAL SPECIFICATIONS

Automatic (A) / Step-by-step automatic (AP) / Manual (E) / Step-by-step manual
Mains power supply (230/115 V~) / FCA and FCC travel limits/ Photocells / Stop/
3-pin molex coupling for encoder / 3-pin molex coupling for receiving module
Motor power supply 24V
Rod lights 24V

3. PREPARATIONS

4. BOARD LAYOUT

Description
230 V~ 50 Hz / 115 V~ 60 Hz
5 W
480 W
500 mA
-20°C +55°C
2 fuses, replaceable + 4 fuses, self-resetting
(EP) / Condo (D)
60 seconds
Adjustable on 7 levels of 5 seconds up to 4 minutes
Adjustable on four levels
Open-Close / Open / Close / Safety dev. test / Battery
/ Flashing lamp 24V
/ Power supply to accessories / Battery charger
168 mm x 176 mm
Pos.
OP
OPEN input radio programming push-button
O/C
OPEN/CLOSE input radio programming push-button
FCA
FCA input signalling LED
FCC
FCC input signalling LED
FSW
SAFETY DEVICES input signalling LED
STOP
STOP input signalling LED
OP/CL
OPEN/CLOSE input signalling LED
OPEN
OPEN input signalling LED
CLOSE CLOSE input signalling LED
DL6
OPEN/CLOSE radio input signalling LED
DL7
OPEN radio input signalling LED
LCD
Display
E607
Pagina 7
Guide for the installer
/ Indicator light 24V
max. 5W /
Description

Advertenties

Inhoudsopgave
loading

Inhoudsopgave