Warmtepomp

Advertenties

Warnings
Water heater
Setting range nominal water temperature
Use temperature range heat pump
Initial refrigerant amount
Equivalent CO2
Refrigerant filling volume with regard to the wa-
ter volume
GWP of the used gas
Certified output at 7° C ambient temperature (CDC LCIE 103-15/B)
Coefficient of performance (COP)*
Power consumption at stabilized speed (Pes)
Heating time (tr)
Reference temperature (Tref)
Drain profile
Max. Mixed water amount at 40° C (nominal
wvalue at 55° C) (V40)
V40
(8 h HC)
td
* Performance measures in ex-factory mode ECO manual at 10°C to 55°C and capacity of
270 litres and 10°C to 52°C and a capacity of 200 litres At atmospheric pressure in accord-
ance with the log in the functional specifications document of brand NF Electric Output
no. LCIE 103 to 15B, stand-alone thermodynamic boilers (based on standard EN 16147).
** Tested in an echo chamber according to ISO3741 and as defined in the technical annex
to the Official Journal of the European Union 2014/C 207/03 as of 3.7.2014.
These appliances are compliant with EC Directive 2014/30/EU on electromagnetic com-
patibility, Directive 2014/35/EU on low-voltage, Directive 2011/65/EU on the restriction of
hazardous substances and Directive 2013/814/EU, amending Directive 2009/125/EC on
eco-design.
Warranty
-/kg
t.eq.
CO2
h.mn
Use
270 litres
°C
50 - 55
-15 - 37
°C
0,850
1,77
kg/l
0,0031
-
2088 (R410A)
3,24
30,8
W
4.27
54,4
°C
XL
-
l
354
427
l
Servicing
200 litres
50 - 55
-15 - 37
0,850
1,77
0,00425
2088 (R410A)
3,09
21,7
2.57
52,5
L
255
299
31