Connection of the protective conductor (PE):
Sensitivity when switching (with regard to the ambient brightness):
Time setting (switching off delay):
Function test:
Ensure that the motion detector is not obscured. Ensure that the coverage area is not restricted by items such as
through large furniture. To set the detection range and the daylight test, turn the knobs to the positions shown. The
motion detector is activated after a warm-up phase of approx. 30s. If no further movement takes place in the
sensing area of the sensor, the sensor switches off.
Technical Data:
Operating voltage:
Maximum power consumption:
Consumption in standby:
Electrical protection:
Protection class:
If a lamp with protective earth contact is connected and a junction box is
not installed, the protective earth must be bridged from the supply line to
the lamp by means of an additional terminal in the housing of the motion
detector.
This setting control can be used to regulate the switch-on sensitivity of this unit
depending on the ambient brightness (between 3 and 2.000 LUX).
The duration of the operating time can be set continuously from approx. 10s to
30min. The timer is restarted if a movement from the sensor is detected before the
set time has elapsed.
220 -240V AC 50/60Hz
Max. 2.000W
Max. 1.000W
< 0,5W
IP65
II