CONTROL PANEL (7) - Figure B
Your portable refrigerator uses a digital control system to adjust the thermostat.
* Power button (A) - ON. / OFF.
1. Connect the refrigerator to a power source, press the power button (A) once to turn the unit on.
2. Press the power button (A) again, the refrigerator will turn off.
* SET button :
Long press SET button for 3 seconds and enter advanced modes:

ITMODE OF VOLTAGE PROTECTION:

The unit has three battery protection functions that protect the normal operation of the refrigerator and protect the
vehicle battery.
These three levels of battery protection:
H3 - high level of protection
for 12 volts: stops at 10.9 volts and starts at 12.2 volts.
for 24 V: stops at 23.8 V and starts operation at 25.2 V.
H2 - average protection level
for 12 V: stops at 9.7 V and starts operation at 11.0 V.
for 24 V: stops at 21.5 V and starts operation at 22.9 V.
H1 - low protection level:
for 12 V: stops at 9.6 V and starts operation at 10.9 V.
for 24 V: stops at 21.3 V and starts operation at 22.7 V.
Briefly press the "+" or "-" button to select the function. The function is set to medium protection level "H2" when the
refrigerator is ready for the first use.
NOTES:
It is recommended to set the battery protection to H2 (medium level) when the unit is used in a car.
It is recommended to set the battery protection to H2 (medium level) or H1 (low level) if it is an external battery or a
backup battery.
Due to the difference in output voltage from different outputs of the vehicle's power supply, if there is voltage
protection (LCD display shows F1), the battery function may be reduced to a lower one (H3 is switched to H2 or H1).
* The "+" button (F) is used to increase the temperature or other settings described above.
* The "-" button (G) is used to lower the temperature or other settings described above.
* Power indicator (C):
- When the refrigerator is on, the indicator light is red.
- When the refrigerator is off, the light goes out.
* Error indicator (D):
- In case of a malfunction, the buzzer will ring continuously.
- Fault codes will appear on the screen.
- The fault indicator (D) will light up in blue.
* LCD display (E): shows
- Displays the temperature and other settings.
- Fault codes may appear on the screen, as below:
F1: Voltage failure
F2: Fan current failure
F3: Compressor start-up error
F4: Minimum compressor speed failure
F5: Controller temperature error
E0: Interrupted sensor circuit
E1: Sensor short circuit
The LCD display allows you to set the temperature from -20℃ to +20℃. The realistically achieved temperature inside
the unit depends on the external conditions. For example, at an ambient temperature of +25℃, the lowest achieved
temperature inside the unit is -20℃. The unit does not have a heating function.