Operating Manual SATAjet 1500 B RP/HVLP
EN
[1-17] Gravity flow cup lid
6.2. Air micrometer (aif flow control knob)
Separate pressure gauge
[3-1]
with control device (see
chapter 15)
Separate pressure gauge
[3-2]
without control device (see
chapter 15)
7. Technical Data
Gun inlet pressure
RP
Operating range
(Field of application)
Compliant
HVLP
Operating range
(Field of application)
Compliant
Compliant legislation
Lombardy/Italy
Spray distance
RP
Operating range
(Field of application)
recommended
HVLP
Operating range
(Field of application)
recommended
Max. spray gun inlet pressure
124
Pressure measurement in
[3-3]
compressed air circuit
[3-4]
SATA adam 2 (see
chapter 15)
0.5 bar - 2.4 bar
max. 1.8 bar
0.5 bar- - 2.4 bar
> 1.8 bar (air cap
pressure > 0.7
bar)
< 2.5 bar (air cap
pressure < 1.0
bar)
10 – 21 cm
17 – 21 cm
10 – 21 cm
10 – 15 cm
10.0 bar
7 psi - 35 psi
max. 26 psi
7 psi - 35 psi
> 29 psi (air cap
pressure > 10
psi)
< 35 psi (air cap
pressure < 15
psi)
3.9" – 8.3"
6.7" – 8.3"
3.9" – 8.3"
3.9" – 5.9"
145 psi