GB
10. Filter Replacement
The combination filter should be replaced after
approx. 4320 operating hours. After approx.
4320 operating hours, the filter change indicator
(REPLACE FILTER) flashes automatically on the
control console of the device. Use only original
Soehnle filters!
Proceed as follows to change the filter:
1. Switch the device off and disconnect the
power plug.
2. Open the device as described in Chapter 9
(2.4).
3. Insert the new combination filter into the
housing. Ensure that the new filter unit is in-
serted correctly.
4. Close the device and fasten the screw cap.
Turn the device right side up and place it on
a solid surface.
5. Reconnect the power cord to a power outlet
and switch the device on.
6. Press the red "Reset button" to reset the oper-
ating hours counter. The button is located be-
hind the three access slots on the side of the
product (1.1). To press the button, use a thin
object (for example, a paper clip). A signal
sounds and the filter reset indicator light disap-
pears. The operating time metre is now reset.
11. Transport and storage
Transport
WARNING!
Always switch the device off before transporting
it. Always disconnect the power plug from the
power outlet.
14
Storage
We recommend carefully cleaning your Airfresh
Clean Connect 500 before storing the device.
Ensure that all parts are clean and dry prior to
storing the device. Store the Airfresh Clean Con-
nect 500 in a cool and dry place.
12. Troubleshooting
Switch the device off and disconnect the power
plug before performing the following tests.
Problem: The device does not work
• Ensure that the Airfresh Clean Connect 500 is
connected to a power source.
• Ensure that the filter is inserted correctly.
• Ensure that the bottom cover is inserted cor-
rectly and close tightly with the screw cap.
Problem: Insufficient airflow
• Ensure that the filter is clean. Please clean the
filter if it is soiled.
• Ensure that air inlet and air outlet are not
blocked or obstructed.
Problem: Excessive noise
• Ensure that no foreign objects are located in
the fan and remove them if necessary.
• Ensure that the filter is clean. Please clean the
filter if it is soiled.
• Ensure that the filter is inserted correctly.
• Ensure that the device is placed securely and
evenly on a solid surface.
Problem: Device shows consistently
high values
• Resetting the sensor: Turn on the device. Press
the filter reset switch (1.1) and run the device
for 2-5 hours (depending on room size). The
sensor is now reset.