Connecting Lines to External Machines

All connecting lines have to be guided in shielded lines. Shielding has to be connected on both sides to the corner shell.
It is not allowed to guide lines parallel to power lines. If a parallel guiding cannot be avoided a distance of at least 0.5 m has to
be observed.
Temperature of lines between: −15 ... +80 °C.
It is only allowed to connect devices which fulfil the request 'Safety Extra Low Voltage' (SELV). These are generally devices
which are checked corresponding to EN 62368-1.

Installation of Data Lines

The data cables must be completely protected and provide with metal or metallised connector housings. Shielded cables and
connectors are necessary, in order to avoid radiant emittance and receipt of electrical disturbances.
Allowable lines
Shielded line:
Sending and receiving lines have to be twisted in pairs.
Maximum line length:
Air Convection
To avoid inadmissible heating, free air convection has to be ensured.

Limit Values

Protection according IP:
Ambient temperature °C (operation):
Ambient temperature °C (storage):
Relative air humidity % (operation):
Relative air humidity % (storage):
Guarantee
We do not take any responsibility for damage caused by:
Ignoring our operating conditions and operating manual.
Incorrect electric installation of environment.
Building alterations of our printers.
Incorrect programming and operation.
Not performed data protection.
Using of not original spare parts and accessories.
Natural wear and tear.
When (re)installing or programming our printers please control the new settings by test running and test printing. Herewith you
avoid faulty results, reports and evaluation.
Only specially trained staff is allowed to operate the printers.
Control the correct handling of our products and repeat training.
We do not guarantee that all features described in this manual exist in all models. Caused by our efforts to continue further
development and improvement, technical data might change without notice.
By further developments or regulations of the country illustrations and examples shown in the manual can be different from the
delivered model.
Please pay attention to the information about admissible print media and the notes to the printer maintenance, in order to avoid
damages or premature wear.
We endeavoured to write this manual in an understandable form to give and you as much as possible information. If you have
any queries or if you discover errors, please inform us to give us the possibility to correct and improve our manual.
94
4 x 2 x 0,14 mm² ( 4 x 2 x AWG 26)
6 x 2 x 0,14 mm² ( 6 x 2 x AWG 26)
12 x 2 x 0,14 mm² (12 x 2 x AWG 26)
with interface V 24 (RS232C) - 3 m (with shielding)
with USB - 3 m
with Ethernet - 100 m
20
min. +5 max. +35
min. −20 max. +60
max. 80
max. 80 (bedewing of printers not allowed)