TABLE "B" - LOGICS
Any modification of parameters/logics must be confirmed by pressing S2 > 5s
DIP
Logic
Default
Transmitter
1
programming
2
BAR / 8K2
Photocell input
3
check
4
Edge input check
Photocells
5
during closing
Safety edge
6
input operation
7
Fast closing
Residential /
apartment
8
building
operation
24 -
SHYRA
INSTALLATION MANUAL
Cross out
Description
setting used
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been
memorized in standard mode via the radio menu.
ON
2- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters.
ON
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
Disables wireless memorizing of transmitters and automatic addition of clones.
OFF
Transmitters are memorized only using the relevant Radio menu or automatically with replays.
IMPORTANT: Disables the automatic addition of new transmitters and clones
Input configured as Bar 8k2 (Fig.G). Input for resistive edge 8K2.
ON
The command reverses movement for 1 sec.
OFF
Input configured as Bar, safety edge (Fig.G).
OFF
The command reverses movement for 1 sec..
ON
Enable safety check on the PHOT input. (Fig.G)
OFF
OFF
Safety check on PHOT input not enabled. (Fig.G)
ON
Enable safety check on the BAR input. (Fig.G)
OFF
OFF
Safety check on BAR input not enabled. (Fig.G)
In the event beam is broken, photocell operation is disabled during opening. During closing, move-
ON
ment is reversed immediately.
OFF
When
OFF
sing. When beam is broken during closing, movement is reversed only once the
photocell is cleared.
SHYRA AC SL
ON
Safety edge with active reversal only when closing, when opening the movement stops
OFF
Safety edge with active reversal in both directions
OFF
SHYRA AC BA
ON
Not used
OFF
Not used
SHYRA AC SL
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
ON
OFF
SHYRA AC BA
Closes 1 second after the photocells are cleared before waiting for the set TCA to elapse.
OFF
Logic not enabled
Sets the
automation type
ON
of operation:
ON = Apartment building
OFF
OFF
OFF = Residential
beam
is
broken,
photocells
Reaction to the START input (wired or radio):
CLOSED
WHILE CLOSING
OPEN
WHILE OPENING
AFTER STOP
Reaction to the OPEN input (wired):
CLOSED
WHILE CLOSING
OPEN
WHILE OPENING
AFTER STOP
Reaction to the PEDESTRIAN input (radio):
CLOSED
WHILE CLOSING
OPEN
WHILE OPENING
AFTER STOP
are
active
during
both
Residential
Apartment building
Opens
Opens
Stops
Opens
Closes
Closes
STOPS + TCA
No effect
Opens
Opens
Residential
Apartment building
Opens
Opens
Opens
Opens
Keep open + TCA
Keep open + TCA
No effect
No effect
Opens
Opens
Residential
Apartment building
Opens partially
Opens partially
Stops
Opens partially
Closes
Closes
STOPS + TCA
No effect
Opens partially
Opens partially
opening
and
clo-