Mounting the hood body
• Hook the hood body onto the screws 12a.
• Fully tighten the support screws 12a.
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe ø 150 or
125 mm, the choice of which is left to the installer.
• To install a ø 125 mm air exhaust connection, insert
the reducer flange 9 on the hood body air outlet and
the adapting ring ø120-125 10a on the reducer flange.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Remove any activated charcoal filters.

Exhausted mode Recommendations and suggestions

Connect the extractor to the exhaust flue through a pipe of minimum diameter 125 mm.
The route of the flue must be as short as possible.
Ideal ducting distance to discharge outlet is maximum of 3 meters straight run, or 2 meters and one 90 degree
bend preferably rigid duct.
Maximum ducting distance should be 3 meters, with one 90 degree bend.
For each additional 90 degree bend, the maximum distance is reduced by 1 meter.
If the ducting is not correct it will increase noise and reduce performance.