1.3 Settings

The EFC18 is set initially so that the temperature sensor starts and stops the chimney fan at either
20 °C, 40 °C or 80 °C. The factory setting is 40 °C.
Setting the temperature
Step
1
The control must be standby (shows "–" in display).
2
Press and hold the button in for 5 seconds and the gure displayed will change to 0,1, 2 or 3.
3
When the required number is displayed, hold down the button until a horizontal line appears ("—").
Setting options:
0 = Fitted without sensor
1 = Automatic start / stop of chimney fan, 20 °C (open re / closed stove / boiler)
2 = Automatic start / stop of chimney fan, 40 °C (open re / closed stove / boiler)
3 = Automatic start / stop of chimney fan, 80 °C (alternative setting for closed stove / boiler:
delayed start / rapid stop)
Always switch o the electricity supply before opening the control unit.