GAS CONNECTION
(Fig. 4) Connect the appliance to the gas cylinder or to the installation according to the prescribed standards in force,
and ensure beforehand, that the appliance matches the type of gas available. Otherwise, see "Adaptation to various
types of gas". Furthermore, check that the feed pressure falls within the values described on the table: "Injectors
characteristics".
Rigid/semirigid metal connection
Carry out the connection with fittings and metal pipes (even flexible pipes) so as to obtain counter stress the inner
parts of the appliance.
N.B.: - token the installation has been carried out, check the perfect sealing of the entire connection system, by using
a soapy solution.
Fig. 4
Electrical connection
(Fig. 5) Prior to carrying out the eleciricat connection, please ensure that:
• the plant characteristics are such as to follow what is indicated on the matrix plate placed at the bottom of the
working area;
Fig. 5
• that the plant is fitted with an efficient earth connection, following the standards and law provisions in force.
The earth connection is compulsory in terms of the law. Should there be no cable and/or plug on the equipment,
use suitable absorption material for the working temperature as well, as indicated on the matrix plate. Under no
circumstance must the cable reach a temperature above 50 °C of the ambient temperature.
Should a direct connection to the network be required, it will be necessary to interpose an omnipolar switch with
34
G 1/2
ISO 7/1
ISO 228/1 (FR)
CABLE-CLAMP