TABLA N°2: Adaptación a un tipo diferente de gas
CATEGORIA APARATO: I2HS , II2H3+ , II2E3B/P , II2HS3B/P30,50, II2ElwLs3B/P
Quemador
Tipo de Gas
Natural G20
Natural G25
Natural G25.1
Natural G27
Auxiliar
Natural G2.350
Butane
G30
Natural G20
Natural G25
Natural G25.1
Natural G27
Semi-
rapido
Natural G2.350
Butane G30
Natural G20
Natural G25
Natural G25.1
Natural G27
Rapido
Natural G2.350
Butane G30
Natural G20
Natural G25
Natural G25.1
Natural G27
Triple-
Corona
Natural G2.350
Butane G30
Diametro
Pressión
Inyectores
mbar
1/100mm
20
69
25
69
25
69
20
75
13
96
30
50
37
44
50
43
20
97
25
97
25
97
20
106
13
131
30
68
37
64
50
60
20
110
25
110
25
110
20
121
13
147
30
78
37
72
50
68
20
123
25
123
25
123
20
145
13
180
30
91
37
86
50
83
Carga Nominal
g/h
l/h
kW
—
85.7
0.90
—
99.7
0.90
—
99.6
0.90
—
104.5
0.90
—
119
0.90
65
—
0.90
65
—
0.90
65
—
0.90
—
179
1.88
—
208.3
1.88
—
208.1
1.88
—
218.5
1.88
—
248.8
1.88
136
—
1.88
136
—
1.88
136
—
1.88
—
228
2.4
—
265.9
2.4
—
265.7
2.4
—
278.8
2.4
—
317.6
2.4
174
—
2.4
174
—
2.4
174
—
2.4
—
323
3.4
—
376.7
3.4
—
376.5
3.4
—
395
3.4
—
450
3.4
247
—
3.4
247
—
3.4
247
—
3.4
11
Carga Reducida
kcal/h
kW
kcal/h
774
0.40
344
774
0.40
344
774
0.40
344
774
0.40
344
774
0.40
344
774
0.40
344
774
0.40
344
774
0.40
344
1617
0.60
516
1617
0.60
516
1617
0.60
516
1617
0.60
516
1617
0.60
516
1617
0.60
516
1617
0.60
516
1617
0.60
516
2064
0.90
774
2064
0.90
774
2064
0.90
774
2064
0.90
774
2064
0.90
774
2064
0.90
774
2064
0.90
774
2064
0.90
774
2924
1.50
1290
2924
1.50
1290
2924
1.50
1290
2924
1.50
1290
2924
1.50
1290
2924
1.50
1290
2924
1.50
1290
2924
1.50
1290