Operation
3.4 Arc Length Adjustment (ArC)
When button 9 is pressed for 3 seconds, arc length function will be active. The factory setting is 0.0. You can
EN
change the arc length setting in the range of +7/-7 by turning the existing button left and right. In the change
made towards +7, the wire contact approaches the nozzle and the arc length becomes longer. In the change
made towards -7, the wire approaches the weld metal and the arc length becomes shorter. After the desired
setting is made, the current button is pressed once to exit the setting.
3.5 MIG Curve
Pre-Gas
Post Gas
Burn Back
Arc On Time
Arc Off Time
Wire Diameter
Thickness
Gas Type
Wire Type
Clicking Adjustment
Crater
Mode
Trigger
Method
Cooling Time
USER MANUAL
Set Voltage
Slow Release
Voltage 0 - 25
On
Crater Open
Pre Gas
Set Voltage
Slow Release
Voltage 0 - 25
On
Crater Open
Pre Gas
Set Wire
Slow Release
Wire 0 - 25
Off
Crater Closed
Pre Gas
Set Wire
Slow Release
Wire 0 - 25
Off
Crater Closed
Pre Gas
Pnt Mode
On
Spot
Pre Gas
Value Range
0,0 - 9,9 sec
0,0 - 9,9 sec
25 - 0 - 25
0,2 - 9,9 sec
0,0 - 9,9 sec
0,8 - 1,6 mm
0,6 - 20,0 mm
82/18, 92/8, %100 Ar, %100 CO2, %97,5/2,5
SG/FE, Flux Rutil, Flux Basic, AIMg 4,5Mn, AIMg5, AIsi 5, AL 99,5
Active / Passive
Active / Passive
Synergic / Smart / Classic / Cell-Gauging / Ruile-Basic / Method
Method / 2 / 4 / 6
MIG / MAG - MMA
1 - 5 min
Crater
Crater
Pnt Mode
Off
2- Position MIG
Factory Setting
0,1 sec
0,1 sec
0 step
0,2 sec
0,0 sec
1,0 mm
1,0 mm
Passive
Passive
2
MIG / MAG
1
EXPERT SERIES
Burn Back
Post Gas
Burn Back
Post Gas
Burn Back
Post Gas
Burn Back
Post Gas
Post Gas
4- Position MIG
6- Position MIG
www.magmaweld.com

Advertenties

loading

Deze handleiding is ook geschikt voor: