CS.DSA.IST-1 / Rev 1.0
9
Remove the inspection port of the lower flue gas passage by undoing the two screws
11
Remove the inspection port of the extractor flue gas passage by undoing the two screws
To ensure correct operation, it is necessary to remove the sawdust deposited on the bottom of the tank
Cleaning the vermiculite components
The vermiculite panels do not require any special maintenance. If necessary, they must be dusted gently using a brush only. To avoid jeopardising
their durability, they must not be cleaned using abrasive sponges, wet cloths or the tube of the ash vacuum device placed directly in contact with it.
the inspected compartment
inside the inspected compartment
13
The pellet tank must be emptied at the end of every season.
10
(fig.
9). After removing the cover, vacuum the residues inside
(fig.
10).
12
(fig.
11). After removing the cover, vacuum the residues
(fig.
12).
24
ENGLISH
(fig. 13)
at least once every 30 days.