4 Checks

Before every shift

• Condition of seals
• Function of safety devices
• Empty the dust container
• Condition and function of the drain hose (closed)
• Condition and cleanliness of the filter

Every 200 hours of operation (monthly)

• Vacuum cleaner seal
• Check Suction hose and accessories for cracks and breakage
• Damage to the power cable
• Filter for tears or holes, replace if necessary
• Condition of the float system and free movement

Every 2000 hours of operation (annually)

• Condition of the suction unit
• Inspection by a professional or an authorised service centre
5 Troubleshooting and repairs
Fault
Low suction
Vacuum not starting
Model variant
1)
Cause
Cover not properly closed
Filter dirty
Container full
Motor protection filter clogged
Water sensor/float has switched
off
Nozzle, tubes or hose clogged
Switch defective
Not connected to power
No power
Power cord defective
Solution
Close cover
Clean
Empty
Clean
Switch off the vacuum cleaner, let
the liquid drain off via the drain
hose, empty the container, clean
the float and filter
Clean
check and replace as necessary
Plug in
Check fuse
Have replaced