Download Print deze pagina

Sebson HF OUT A Handleiding pagina 10

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 26
sensor has a power of about 0.2mW. Thus the power of the radiation is about 1/ 5,000th of that of a mobile phone.
The product can therefore be used without any risk.
Detection area (Fig 2):
The detection range of the motion detector is approx. 5-15m and 180° (free area) at a mounting height of 1,5-3,5m
on the wall. In closed rooms the detection distance can be lower, according to room layout.
Connection of the protective conductor (PE):
Sensitivity when switching (with regard to the ambient brightness):
Time setting (switching off delay):
Reach Setting:
Function test:
To set the detection range and the daylight test, turn the knobs to the positions shown. The motion detector is
activated after a warm-up phase of approx. 30s. If no further movement takes place in the sensing area of the
sensor, the sensor switches off.
When connecting a lamp with protective conductor contact, the
protective conductor must be bypassed from the supply line to the lamp
with the aid of an additional terminal in the in-wall socket.
This setting control can be used to regulate the switch-on sensitivity of this unit
depending on the ambient brightness (between 3 and 2.000LUX).
The duration of the operating time can be set continuously from approx. 10s to
12min. The timer is restarted if a movement from the sensor is detected before the
set time has elapsed.
With this setting controller, the detection range of approx. 5m to 15m can be set.
Turning the adjuster to the left will extend the range.
10

Advertenties

loading

Deze handleiding is ook geschikt voor:

Hf out aa