3
TECHNICAL SPECIFICATIONS
Power supply voltage
Absorbed power
Motor max. load
Accessories max. current
(+24V)
BUS Accessories max.current
Operating ambient tempera-
ture
Fuses
Function logics
Work time (time-out)
Pause time
Terminal board inputs
Connector inputs
Terminal board outputs
Programmable functions
Learning functions
Integrated radio channels
type
3.1 DESCRIPTION OF COMPONENTS
J1
POWER SUPPLY connector
J2
SERVICE LIGHT command terminal-board
J3
FLASHING LAMP terminal-board
J4
ELECTRIC LOCK terminal-board
J5
COMMANDS terminal-board
J7
MOTOR 1 terminal-board
J8
MOTOR 2 terminal-board
J9
Rapid connection for XF MODULE
J10
BUS terminal-board
J11
BATTERY connector
SW1
SET UP push-button
SW2
SPEED push-button
SW3
LOGIC push-button
DS1
Programming Dip-switch
F1
Accessories protective fuse
F2
Fuses protecting transformers and motors
LED
Signalling LEDs
230Vac (+6% -10%) - 50Hz
10W
150W x 2
250 mA
400 mA
-20°C - +55°C
F1 = self-resetting;
F2 = T2A-250V
EP , A
1 minute (fixed)
Varies according to learning
(max. 10 min.)
Open A, Open B, Stop, BUS
(I/O)
Power supply, battery
module XF 433 or XF 868
Motors, flashing lamp, power
supply to accessories,
electric lock, service light
contact (90 sec fixed)
Logic (A, EP), Speed (high
13°/sec and low 10°/sec)
Pause time, leaf 2 delay at
closing
DS, SLH (max 250 channels)
LC (max 250 channels - FOR
SOME MARKETS ONLY)
3.2 DESCRIPTION OF TERMINAL-BOARDS
Terminal and/or
terminal-board
1
2
J5
3
4
5
J10
RED terminal
J2
GREY terminal
J3
ORANGE terminal
J4
BLUE terminal
J7
J8
Leaf 1 means the leaf which opens first during
the opening operation.
The service light control is active during the
entire gate opening or closing movement and
for the successive 90 seconds.
3.3 ANTI-CRUSHING FUNCTION
If the gate detects an obstacle during the opening or closing
movement, the anti-crushing function activates and reverses
the sense of direction of the operator, thus increasing the safety
degree of the automated system.
The sensitivity of the anti-crushing device can be adjusted with
the dip-switch no.3 (see par.6.2).
4 PROGRAMMING THE LOGIC
The function logic can be selected at any time by pressing
push-button SW3.
The selected logic is then displayed on LED LD7:
LED on
= AUTOMATIC logic (A)
LED off
= SEMIAUTOMATIC STEPPED logic (EP)
5 PROGRAMMING THE SPEED
The function logic can be adjusted at any time by pressing
push-button SW2.
The selected logic is then displayed on LED LD8:
LED on
= HIGH speed (13 °/sec)
LED off
= LOW speed (10 °/sec)
3
Description
Device connected
Power supply for
+24V
accessories
GND
Negative
Device with NC
contact which causes
STOP
the automated
system to shut down
OPEN B
Device with N.O
contact (see chap.
FUNCTION LOGICS)
OPEN A
Safety devices with
BUS
BUS technology
Service Light control
SERVICE
output (connect a
LIGHT
relay coil at 24Vdc-
100mA max)
Flashing lamp 24Vdc
LAMP
- 15W
Electric lock 12Vac or
LOCK
24 Vdc (to be installed
on leaf 1)
MOT1
Motor 1 (leaf 1)
MOT2
Motor 2 (leaf 2)