Assembly transport wheels
1. Secure the wheel axle (5) using the two hexagon head
screws M6x30 and install the cotter pins.
Secure the cotter pins against dropping out by
2
bending their ends using nippers and slide the washers (Ø
15.5) on the wheel axle.
3. Slide the wheels (6) and the washers on the wheel axle.
Secure the wheels using the securing pins (7).
16
After assembly, allow the device to stand vertically for at
least one hour before powering it up. In this way, the refrigerant
in it can settle.

Location of the air dehumidifier

Location

If possible, the air dehumidifier should be placed in the middle
of the room in order to have a good air circulation in the whole
room.
If this is not possible, locate the air dehumidifier so that air can
be sucked and discharged unhindered.
Keep a minimum distance of 10 cm to walls.
Place the air dehumidifier
 horizontally to ensure that the condensed water can flow
off unhindered
 away from a heat source (e.g. a radiator).
Make sure that windows and doors of the room to be
dehumidified are closed.

Electric supply

Compare the voltage listed on the device's type plate, e.g. 230
V / 50 Hz, with the mains voltage and connect the air
dehumidifier to a suited and and properly earthed electrical
socket.
Use an electrical socket with a rated voltage of 230 V with a
fault-current circuit breaker (30 mA).

Power system fuse protection

10 A