19 Jumper J1 to adjust the output level
(position hi = +10 dB)
20 Switching input to trigger the replay of an
emergency message (M6); to be connected
to the corresponding connection cable of the
amplifier
21 Additional audio output with a stereo signal
(not required when used with amplifiers from
MONACOR)
22 Jumper PLAY MODE SELECTOR to select the
replay mode for the messages M1 – M6
replay after the button START/ STOP (14)
or REPEAT/ STOP (13) was pressed
immediate (multiple) replay when the
message is selected by means of the
buttons M1 – M6 (15)
23 Additional input for DCF77 radio clock signals
[not required when used with amplifiers from
MONACOR as the connection is made via the
terminals of the connection plate (18)]
24 Connection jack for remote control of the
module via the zone paging microphone
PA-1120RC, PA-6000RC or PA-2400RC; con-
nect the jack to the corresponding connection
cable of the amplifier
25 Jack for connection to the connection plate
(18) via the ribbon cable supplied
26 Jack for power supply and for the audio out-
put; to be connected to the corresponding
connection cable of the amplifier
27 "Busy" LED, will light up during recording
and replay

2 Safety Notes

The insertion module corresponds to all relevant
directives of the EU and is therefore marked
with
.
The insertion module corresponds to the rel-
evant UK legislation and is therefore marked
with UKCA .
The insertion module must be installed by
skilled personnel only .
The insertion module is suitable for indoor
use only . Protect it against dripping water and
splash water, high air humidity and heat (ad-
missible ambient temperature range: 0 – 40 °C) .
Do not operate the device with the installed
insertion module and immediately disconnect
the device from the power supply
1 . if the insertion module, the device or the
power supply cable is visibly damaged,
2 . if a defect might have occurred after the
device was dropped or suffered a similar
accident,
3 . if malfunctions occur .
In any case the insertion module or the entire
device must be repaired by skilled personnel .
For cleaning only use a dry, soft cloth; never
use water or chemicals .
No guarantee claims for the insertion module
and no liability for any resulting personal dam-
age or material damage will be accepted if the
insertion module is used for other purposes
than originally intended, if it is not correctly
installed or operated, or if it is not repaired in
an expert way .
If the insertion module is to be put out
of operation definitively, dispose of the
module in accordance with local reg-
ulations .

3 Applications

The insertion module PA-1120DMT is a mes-
sage storage module for storing and replaying
26 voice messages . Using a memory card (type
"microSD[HC]"), externally created recordings
can be copied to the memory of the insertion
module . The integrated clock with a DCF77 radio
clock receiver allows for time-controlled message
replay . For remote-controlled message replay and
for emergency message replay, switching con-
tacts can be used .
The insertion module has been especially
designed for PA systems and is suitable for in-
stallation e . g . in the following devices from
MONACOR:
PA-1120
PA amplifier for 5 zones
PA-1240
PA-1200
PA amplifier for 4 zones
PA-1200EX Basic unit for 2 insertion modules
PA amplifier for 10 zones
PA-2410Z
PA-2420Z
PA amplifier for 20 zones
PA-5240
PA amplifier for 5 zones
PA-5480
PA-6240
PA-6480
PA amplifier for 6 zones
PA-6600
15

Advertenties

Inhoudsopgave
loading

Gerelateerde Producten voor Monacor PA-1120DMT

Deze handleiding is ook geschikt voor:

0174580

Inhoudsopgave