PUSHBUTTON / KEY-OPERATED SWITCH (OPTIONAL)
The control board / drive can be activated using various inputs.
This can be done using a hand-held transmitter or key-operated
switch (terminals 13-15)).
Hand-held transmitter = see Teaching the hand-held transmitter
13-14 = input control 1. Normal operation
13-15 = input control 2. Active for special settings
(see description) Menue P12+P13
EMERGENCY STOP (OPTIONAL) 600084
A switch can be connected to stop or disable the unit. The movement
of the wings is stopped immediately. Terminals 13 and 16 must be
bridged if no switch is installed.
Cable cross-section: 0,5 mm
Voltage: 12/24 volts AC/DC.
GATE MONITOR / LIGHTING (OPTIONAL) COM/NO
A 24 V/3 W light bulb can be connected to monitor the status of the
gate. Alternatively, a yard lighting system can be used by adding a
relay.
Setting: see description "Jumper"
Cable cross-section: 0.5 mm
FLASHING LAMP (OPTIONAL) FLA24-2 COM/NO
A flashing lamp can be connected to the control board. It warns when
the gate is being moved. The flashing light should be fitted as high as
possible and in good clear view. The control board emits a constant
signal that the lamp converts to a flashing signal.
Setting: see description "Jumper 3"
Cable cross-section: 0.5 mm
Voltage: 24 V DC
24 VDC - OUTPUT (Terminal 8+9)
For relay infrared senors or other devices (e.g. receivers)
max.500 mA
Do not use any fixed copper lines. Do not lay any 230 volt
cables in parallel and do not lay any 2 cables in the same
cable trunking.
CONTACT STRIP (OPTIONAL) 600213-2
Safety edges with permanent monitoring can be connected via the Interface Box. The Interface Box is connected to the outputs of the photo cell(s).
Cable cross-section: 0.5mm
2
600176 profile size per 1 m
600152 Profile size mounting set
600077-1 Mounting rail 2 m
G-Intset "Profi" transmission set for mounting the strips on the gate wing
G-NSPG45/4 Transmission of signal by means of helix cable (max 8 m in width)
G-AC1103 Strain reliefs/box for helix cable
ANTENNA (OPTIONAL) ANT4X-1LM
If the radio adapter 801719-6 is being used, then terminals 17 + 18 remain vacant. An outdoor antenna is connected directly to the radio adapter.
A larger range (radio) can thus be achieved. Mount the antenna as high as possible.
Do not use any fixed copper lines. Do not lay any 230 volt cables in parallel and do not lay any 2 cables in the same cable trunking.
2
or more.
2
or more.
2
or more.
or more
9 10 11 12 13 14 15 16 17 1
1
2
3
4
5
6
7
8
9 10 11 12 13 14
5
6
7
8
9 10 11
COM NO