Download Inhoudsopgave Inhoud Print deze pagina

Spare Parts; Disposal; Ce Declaration - PLYMOVENT SFS Gebruikershandleiding

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

problem
cause
Indicator
Indicator defective.
extinguished.
Control PCB
defective.
24 VAC supply
defective.
Indicator keeps
Filter saturated.
blinking.
Cleaning mechanism defective:
- 24 VAC magnetic
valve defective.
- Control PCB
defective.
- Cleaning
mechanism
defective or worn.
- No compressed air
or compressed air
pressure too low.
- Pressure difference
switch defective.
SFS does not react
Reset/start button
to pressing the
defective.
reset/start button.
Control PCB
defective.
24 VAC supply
defective.
8

spaRE paRts

The following spare parts are available for the product (refer to
Fig. I on page 38).
• Address your order to your supplier and always state the
data below:
-
product name, supply voltage and serial number
(see the identification plate);
-
article number of the particular part;
-
description;
-
quantity.
art. no.
Description
0042000040
Membrane valve
0046030010
Pressure relief valve 6-10 bar
0324150120
Control lamp 28V, yellow
0326701020
PC board control MFS/SFS
0328290010
Reset/start button
0401102030
Sealing ring
0690150070
Lock SFD/SFS
0806010160
Handle barrel SFS
0806014020
Cover star knob M8
0809040040
Cover Ø 160 mm
0810100050
Sealing membrane valve
9822010010
Sealing SFD/SFS (2,5 m)
9824000030
Pressure difference switch SFS (670 Pa)
9824000090
Piston mechanism MFS/SFS/SCS
9850060110
DuraFilter FCC-30
9850060120
Barrel 15L for filter residue SFS (reusable)
0102080100
Spark arrester
0507320010/061112/D SFS
All manuals and user guides at all-guides.com
solution
Replace indicator.
Replace control PCB.
Remedy the 24 VAC
supply.
Replace.
See chapter 6.
Replace magnetic coil
or the diaphragm.
Replace PCB.
Replace the cleaning
mechanism.
Check the compressed
air system and/or the
compressed air
connection.
Replace the pressure
difference switch.
Replace reset/start
button.
Replace control PCB.
Remedy the 24 VAC
supply.
(not shown)
MFS/SFS (HD)
9

DispOsaL

After life of the product, dispose it of in accordance with
federal, state or local regulations.

cE DEcLaRatiON

cE declaration of conformity for machinery
We, Plymovent Manufacturing B.V., Wezelkoog 11, 1822 BL
Alkmaar, the Netherlands, herewith declare, on our own
responsibility, that the product(s):
- SFS
which this declaration refers to, is/are in accordance with the
conditions of the following Directives:
- Machine Directive 2006/42 EC
- EMC 2004/108 EC
and is/are in conformity with the following harmonized
standard(s) and/or other such normative documents +
amendments, if any:
- EN-ISO 12100:2010 (safety of machinery)
- EN-ISO 13857:2008 (safety distances)
- EN-IEC 60204-1:2006 (electrical safety)
Alkmaar, the Netherlands, 6 November 2012
Ir. F. Coehoorn
Vice President Research & Development
An installation is defined as a combination of several finished
products or components that are assembled by an installer at
a given place. The various parts of the installation are intended
to operate together in a particular environment and to perform
a specific task. The entire installation must comply with the
relevant directives and standards. The assembly instructions
given by the manufacturer, as well as the whole method of
installation, must be in accordance with good engineering
practices within the context of installations, as well as
installation rules. Considering the above, the installer will be
responsible for completing the installation and issuing the final
CE Declaration of Conformity.
EN - 10

Advertenties

Inhoudsopgave
loading

Inhoudsopgave