Download Print deze pagina

Magmaweld COMPACT ECO Series Gebruikershandleiding pagina 33

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 239
COMPACT ECO SERIE
Error Code
Error
Torch Connection
E10
E11
System Error
E12
E13
Wire Feeder Error
E14
System Error
Remote Control
E15
Communication
E16
E17
System Error
E18
Thermal
E19
Protection
(Secondary)
E20
E21
System Error
E22
E23
Inlet Pressure
E26
Torch Shield Not
E27
Installed
E28
System Error
www.magmaweld.com
• The torch or torch connections
Error
may be faulty
• There may be a hardware error
• There may be an error in wire feeding
• There may be a hardware error
• There may be an error in the remote
control connections
Error
• There may be a hardware error
• The duty cycle of your machine may
have been exceeded
• Fan may not be working
• The front of the air inlet - outlet ducts
may be blocked
• The machine working environment
may be too hot or stuffy
• There may be a hardware error
• Inlet pressure may be low
Low
• Torch shield may not be installed or
properly fitted
• There may be a hardware error
• Check torch and torch connections
Cause
• If the problem continues, contact the
• Contact the authorized service
• Check wire basket, reel / reel press
• If the problem continues, contact the
• Contact the authorized service
• Check remote control connections
• If the problem continues, contact the
• Contact the authorized service
• Allow the machine to cool down by
• If the problem continues, contact the
• Visually check if the fan is working
• If the problem continues, contact the
• Unblock the front of the air ducts
• If the problem continues, contact the
• Make sure that the working
• If the problem continues, contact the
• Contact the authorized service
• Check your air / gas connections,
• Make sure that the torch shield is
correctly fitted to the machine
• If the problem continues, contact the
• Contact the authorized service
Maintenance and Service
Solution
authorized service
and torch connections
authorized service
authorized service
waiting for a while. If the fault
disappears, try to use the machine at
lower amperage values
authorized service
authorized service
authorized service
environment of the machine is not
excessively hot or stuffy
authorized service
make sure that the inlet pressure
is appropriate. If the inlet pressure is
normal, contact the authorized
service
authorized service
USER MANUAL
33
EN

Advertenties

loading