32
Maintenance and Service
Fan is not operating
Failure
EN
The value 0000 will be displayed
on the screen
4.4 Error Codes
Error Code
E01
E02
E03
E04
E05
E06
E07
E08
E09
USER MANUAL
• Electronic card / fan failure
• The welding parameters have not
been selected appropriately
Error
• The duty cycle of your machine may
have been exceeded
• Fan may not be working
Thermal
Protection
(Primary)
• The front of the air inlet-outlet ducts
may be blocked
• The machine working environment
may be too hot
Mains Voltage
• Mains voltage may have decreased
Low
Mains Voltage
• Mains voltage may have increased
High
Current / Voltage
• There may be a hardware error
Reading Error
Temperature Sensor
• There may be a hardware error
Reading Error
Water Cooling
• There may be an error in the water
Unit Error
cooling unit
System Error
• There may be a hardware error
• Contact the authorized service
Reason
• All parameters such as wire
• Allow the machine to cool down by
Cause
• If the problem continues, contact the
• Check visually whether the fan is
• If the problem continues, contact the
• Open the front of the air ducts
• If the problem continues, contact the
• Make sure that the working
• If the problem continues, contact the
• Check the mains connection cables
• Check the mains connection cables
• Contact the authorized service
• Contact the authorized service
• Check water cooling unit connector
• Make sure there is water circulation
• If the problem continues, contact the
• Contact the authorized service
COMPACT ECO SERIES
Solution
type, gas type, etc. must be
selected according to your
welding method
Solution
waiting for a while. If the fault
disappears, try to use the machine at
lower amperage values
authorized service
working or not
authorized service
authorized service
environment of the machine is not
excessively hot or stuffy
authorized service
and the voltage. Make sure the
correct voltage input is provided.
If the mains voltage is normal,
contact the authorized service
and the voltage. Make sure the
correct voltage input is provided.
If the mains voltage is normal,
contact the authorized service
and torch inlets/outlets
authorized service
www.magmaweld.com