We recommend the following cleaning tem-
peratures:
– Light contaminations
3 5
– Contaminations containing protein, i.e.
in the food processing industry
6
– Vehicle cleaning, machine cleaning
6
5
DANGER
Scalding danger!
Set temperature regulator to desired
temperature.
Changing the working pressure and
the feed volume will also change the water
temperature.
Secure the trigger gun. To do so, push
the safety catch towards the front.
Set dosing value for detergent to 0 .
Set the appliance switch to 1 (opera-
tion with cold water).
Open the hand spray gun and rinse the
appliance for at least 1 minute.
DANGER
Danger of scalding by hot water. After oper-
ation with hot water, the appliance must be
operated with an open gun with cold water
for at least five minutes to cool it off.
Shut off water supply.
Open the hand spray gun.
Switch on the pump with the power
switch and allow to run for about 5-10
seconds.
Close the hand spray gun.
Set the appliance switch to 0/OFF".
Pull main plug out of socket with dry
hands only.
Remove water connection.
Activate hand spray gun until device is
pressure less.
Secure the trigger gun. To do so, push
the safety catch towards the front.
Lock in the steel pipe into the holder of
the appliance hood.
Roll up high pressure hose and electri-
cal conduit and hang them into the re-
spective holders.
Do not twist high pressure hose and
electrical conduit.
ATTENTION
Risk of damage! Frost will destroy the appli-
ance if the water has not been completely
drained.
Store in a frost free area.
If it is not possible to store frost free, shut
down device.
For longer work breaks or if a frost free stor-
age is not possible:
Empty detergent tank.
Drain water.
Flush device with anti-freeze agent.
Screw off water supply hose and high
pressure hose.
Unscrew the drain screw of the boiler
on the bottom of the boiler and empty
the boiler.
Operate device for max. 1 minute until
the pump and conduits are empty.
Observe handling instructions of the
anti-freeze agent manufacturer.
Fill commercial grade anti-freeze into
the boiler.
Switch on appliance (without heater)
until the appliance has been completely
rinsed.
A certain corrosion protection is achieved
with this as well.
EN