Troubleshooting
Troubleshooting
Charging terminals connected to wrong poles
Cause
Remedy
Charging terminals short-circuited
Cause
Remedy
Cause
Remedy
Over-temperature
Cause
Remedy
Cause
Remedy
Safety cut-out
Cause
Remedy
Cause
Remedy
Cause
Remedy
All manuals and user guides at all-guides.com
Charging terminals connected to wrong poles
Swap charging terminals round
Short-circuit on the charging terminals
Rectify short-circuit on the charging terminals
Battery not detected
Check that charging terminals are properly connected, press
Start/Stop button for 5 seconds
Over-temperature - charger too hot
Allow charger to cool down
Air inlets and outlets covered
Ensure air inlets and outlets are not obstructed
Battery faulty
Check battery
Charger incorrectly set
Check settings: Ah, voltage
Incorrect battery type (e.g. NiCd), incorrect number of cells
(voltage)