Troubleshooting
To be able to use the device again, you must remove the
overload and unplug the device once from the socket then
plug it back in again. Alternatively, you can wait 30 minutes
after removing the overload ("restart lock"). The device can
then be switched on again. The device is not automatically
switched on after the restart lock has expired.
8.4
Error codes and flashing sequences
Flashing code
Meaning
Short orange
Radio trans-
flashing
mission/at-
tempting to
transmit
1x long green
Transmission
lighting
confirmed
1x long red
Transmission
lighting
failed
Slow orange
Pairing mode
flashing (every
active
10 seconds)
38
Solution
Please wait, until
transmission has
been confirmed.
You can continue
operation.
Please try again
(s. „8.1 Command
not confirmed" on
page 36).
Please enter the
last four numbers
of the device
number to confirm
(see „5.1 Installa-
tion and pairing"
on page 33).
1x long red
Duty cycle
lighting
exceeded or
transmission
failed
6x long red
Device defec-
flashing
tive
1x orange
Test display
and 1 x green
lighting (after
plugging into a
socket)
9
Restore factory settings
The factory settings of the device can be re-
stored. If you do this, you will lose all your set-
tings.
To restore the factory settings of the pluggable switch
and meter, please proceed as follows:
•
Unplug the device from the socket (see figure 2).
•
Plug in the device into the socket again while
Restore factory settings
Please try again
(see „8.1 Com-
mand not con-
firmed" on page
36 or „8.2 Duty
cycle" on page
37).
Please see your
app for error mes-
sage or contact
your retailer.
Once the test dis-
play has stopped,
you can continue.
39