Remove the connection cable on the
NEERIM extractor unit and connect it to a
power socket which has to be fitted inside
the space where the extractor is to be built
in.
If a minilift is used during the fitting,
remove the perimeter extraction panel.
Unhook the little safety chains on the front
side and disconnect the light plugs on the
rear side with the hinges.
Loosen the book screws in the hinge
construction on the rear side. Attention:
these are locked with a liquid thread locker
(such as Loctite®).
Mount the extractor as close as possible
to the ceiling.
To reduce resistance, keep the ducting
traject as short as possible and fit it in a
smooth run with as few bents as possible.
Always use a duct as large as possible,
never smaller then the connector on the
external motor or extractor itself.
Connect the connector cable again with
the extractor. Connect the 7-core cable
with the external motor. Place the
extractor in the cut out in the ceiling.
Fit the extractor to the beams with the
supplied screws.
Replace the perimeter extraction panel as
it was removed. Fit the panel with the
All manuals and user guides at all-guides.com
book screws and a liquid thread locker.
Connect the lamp connectors. Place the
safety chains.
(01)
EN 7 Installation