Download Inhoudsopgave Inhoud Print deze pagina

Victron energy BlueSolar PWM Charge Controller Handleiding pagina 10

Lcd-usb
Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 11
6.Specifications
BlueSolar PWM Charge
Controller
Battery Voltage
Charge & Load Current
Charge mode
Automatic load
disconnect
Maximum solar array
voltage
Solar voltage range
Self-consumption
Protections
Solar Panel
Recommended solar panel
array
Max Solar Input Power
USB outputs
Voltage
Current
Default settings
Absorption charge
(b01)
1
Float charge (b01)
1
Load disconnect (b01)
Load reconnect (b01)
Enclosure
Terminal size
Weight
Dimension (h x w x d)
Mounting
Humidity (non
condensing)
Operating temperature
Cooling
Protection class
Standards
Safety
EMC
1
See also 3.1 Battery type setting.
2
[V] values for 24V system.
12V|24V|5A
12V
24V
5A
Reverse polarity connection of the solar panels.
Reverse polarity connection of the battery.
60W
120W
1
1
12V|24V|10A
12V
24V
12/24V Auto Select
10A
PWM, Time and Lighting Control
Yes
55V
15-28V [30-55V]
<10mA
Low voltage disconnect.
130% load: Shuts down after 60sec.
160% load: Shuts down after 5sec.
Short circuit: immediate shut down.
Over-temperature protection.
36cell [72cell]
120W
240W
5V
2A (total from 2 USB outputs)
14.4V [28.8V]
13.7V [27.4V]
11.2V [22.4V]
12.6V [25.2V]
6mm² / AWG10
150gr
96 x 169 x 36 mm
Vertical wall mount, indoor only
Max. 95%
-35°C to +60°C (full load)
Natural convection
IP20
EN60335-1, IEC62109-1
EN61000-6-1, EN61000-6-3
12V|24V|20A
12V
24V
20A
2
2
240W
480W
2
2
2
2

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Scc010020050Scc040020050Scc010010050Scc010005050Scc010030050

Inhoudsopgave