6.
Cleaning and maintenance
6.3

Automatic spool cycle

The automatic spool function is designed to prevent clogging of the soap tubes and to prevent the
waterline from being infected by Legionella and other waterborne bacteria. The automatic spool function
will initiate after a minimum amount of time the soap has not been in use. This has been set by default at
2 weeks.
If the soap has not been in use for 2 weeks, the system will perform the following steps on the liquid that
was last used 2 weeks ago:
Step 1: The soap pump will operate for 30 seconds
Step 2: Cold water flows for 60 seconds
Note: It is possible to change the frequency of the auto spool function for more frequent water flushing,
however it is not possible to change the frequency of the auto spool function for soap flushing.
6.4
*Replacing the pouch / bottle
Once the system does not dispense soap anymore, the pouch / bottle needs to be replaced.
Refer to fig. G for the correct installation of the pouch.
*Only available for models with integrated dispenser
6.5

*Priming the tubes

After installation of the pouches and connecting the power, the tubes need to be primed for the first time.
The prime functions can be activated during the first 5 minutes of power on. When the procedure has
been completed, the tubes are clean and free of air bubbles.
To prime the soap tube: Activate sectors
2 & 3 at the same time immediately after
turning on the power.
Keep hands over sectors 2 & 3. The
prime mode will activate after 2 seconds.
Keep sectors 2 & 3 activated until soap is
dispensed from the soap outlet.
*Only available for models with integrated dispenser