All manuals and user guides at all-guides.com
25. Tips and notes
•
Light refraction and sunlight can cause measuring errors during
outdoor use. Perform measurements under suitable light conditions.
•
When using the product outdoors, protect it from moisture and
humidity.
•
The following surfaces can affect the measurement due to their
physical characteristics:
- Transparent surfaces (e.g. glass, water)
- Reflecting surfaces (e.g. glass, shiny metals)
- Porous surfaces (e.g. insulating materials)
- Structured surfaces (e.g. roughcast, natural stone)
•
Attach the hand strap to the eyelet (N).
•
If needed, mount the product to a suitable tripod with a socket
diameter of 6.35 mm (1/4").
26. Troubleshooting
Code
Err01
Err02
Err03
Err04
Err05
Err06
Cause
Measurement range
exceeded
Reflected signal too
weak
Beyond display range
(max. value: 99999)
Calculation error
Batteries weak
Beyond/below
operating temperature
Solution
Observe the correct
measurement range.
Choose another measurement
surface.
Measure in smaller increments.
Repeat the process.
Replace the batteries.
Observe the correct operating
temperature.
67