Download Inhoudsopgave Inhoud Print deze pagina
Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

TECHNICAL DATA:

Motor voltage
Nominal power
Max. power
Max. thrust
Spindle travel
Cycles/24h
Rated operation time
GATE TYPES
The location of the motor installation depends on the type of gate.
If the gate stop is on the floor the motor should also be installed as
low as possible in order for the gate not to be distorted. Only use
frame elements for fastening.With steel gates the fittings should be
fastened to the main frame. If you are not sure about the stability of
the frame in question then reinforce it.
With wooden gates the frame has to be drilled through
completelywhere the fittings are to be fastened. Attaching a plate
from the outside is recommended in order to prevent fastening from
becoming loose. Thin wooden gates must be reinforced additionally
as they do not withstand the strain otherwise.
Max gate width/weight
Max gate height
Specifications calculated without windload
For gates opening towards the outside (accessory: 50-19503) both parameters gate weight and wing length are to be reduced by 25%.
GATE CONFIGURATION
How far must the gate wing open?
90 degrees or up to 105 degrees.
Different opening angles of the wings: (inclined gateways)
The motor has no ability at all to operate different opening angles.
It is essential to check the following before installation:
If you have 2 gates (1Pair) you may findthey have an overlap and one of them
has to open first if so we will call this Gate 1 and the other one Gate 2.
Gate 1 will open first and close second and should be connected in to PCB as
Motor Master.
Gate 2 will open second and close first and should be connected in to PCB as
Motor Second.
GATE STOPS
A SWING GATE NEEDS A FIXED GATE STOP IN BOTH THE OPEN AND
CLOSE POSITIONS. Gate stops save wear and tear on the motor, gate and
fittings. Operating a gate without fixed limit stops results in poor performance. It is
often dangerous, leads to premature wear and voids your warranty!
24V
10W
40W
300daN
300mm
5-10
4 min
2,5m per wing / 150Kg
2,0m per wing / 200Kg
1,5m per wing / 250Kg
1,5m
2
A
C
E
105°
90°
105°
90
0
B
D
F
90°
90°
105°
90
0

Advertenties

Inhoudsopgave
loading

Inhoudsopgave