AIR SOURCE, FITTINGS, AND PRESSURE CONTINUED
A GX4
Gas Monitor, Part No. 08-400, is recommended to monitor Carbon Monoxide,
®
Oxygen, and Hydrogen Sulfide. (Other gas sensors may become available in the future.)
This can help a system comply with OSHA regulation 1910.134(i)(7), EN 12021, and AS/NZS
1715.
BREATHING AIR PRESSURE
The air pressure must be continually monitored at the point of attachment. Air pressure
must be read from a reliable pressure gauge, while the respirator has air flowing through it,
as required by applicable standards and regulations. Refer to the instruction manual for the
respirator for the Breathing Air Pressure Table to determine the correct air pressure settings
for your setup.
WARNING
regulator to not allow enough air into the unit to work properly or cause the unit to explode.
6
RADEX AIRLINE FILTER
The air pressure supplied to the Radex
exceed 125 psi (8.6 Bar). Exceeding this air pressure could cause the
Airline Filter should not
®

Advertenties