Optional Equipment
Check and replace as needed:
Main line pre-filter element.
Micro-mist filter element.
Replacing the Cartridge and Cleaning the unit
1.
Shut off the air supply to the Radex
opening the pressure release valve.
WARNING
2.
Remove the bolts from the lid and separate the lid from the body.
3.
Remove the cartridge and dispose in an appropriate disposal area.
4.
Clean and dry the inside of the filter body with water, mild detergent. and a cloth
or paper towels to remove any contaminants, do not clean with volatile chemicals.
Irritation or sickness may result from lack of cleaning the inside of the Radex
5.
Check the o-rings (04-919) and replace if damaged.
6.
Insert a new filter cartridge and reassemble the lid, tighten the bolts in the pattern drawn
in (Fig 5.1). Tighten bolts to 10ft/lb torque.
7.
Record the data on the sticker supplied with the filter cartridge and place onto the
Radex
Airline Filter body.
®
FIGURE 5.1
WARNING
filter itself may be hazardous. Take appropriate precautions when handling to avoid
exposure to released contaminants; a company disposal procedure may needed.
Airline Filter and release all air from the body by
®
Pressurized air in the filter could cause lid to forcefully blow off
during removal, resulting in serious injury.
Depending on the contaminants filtered by the Radex
PRODUCT CARE
Do not apply paints, solvents, adhesives or
self-adhesive labels except as instructed by
RPB
. This product may be adversely affected
®
by certain chemicals.
housing.
®
, the used
®