Pressing the Humidity Button activates automatic mode. You can select the desired humidity
level by pressing this button repeatedly until the required humidity level is displayed (from 45% to
75% in increments of 5%). Once you select your desired humidity level, simply stop pressing the
button and your humidity level will be set. Wait another 5 seconds and the numeric value on the
LCD display will switch to the current humidity level as measured by the built-in Hygrostat. When
the humidity level in the room reaches the set humidity level, the machine will go into automatic
sleep state and stop producing mist. When the room's actual humidity level drops below your set
humidity level then the machine will start producing mist again.
You can deactivate automatic mode very easily by pressing the humidity button until you reach
75% RH. Press the button one more time and you will now be in manual mode.
Pressing the Ion Button will activate the negative ion generator and start sending healthy
negative ions into the air. It will be represented by the tree icon displayed on the LCD screen.
The Timer Button sets the timer. The timer function determines how many hours the humidifier
will operate. You can set the timer simply by pressing it once for each two hours that you would
like to run the unit. You can set the timer from 1 hour to 12 hours. As time passes, the time value
decreases until it goes to 00:00 and the machine shuts off.
If the humidifier should run out of water, you will hear a beeping sound before the machine will
automatically shut off. The LCD screen will display the Empty Water Tank icon.
Troubleshooting
The following is a troubling shooting guide to help you solve any issues that you may have with the
operation of the Clean Air Optima CA-603.
TROUBLESHOOTING

Possible reasons

Trouble
Power icon is off or does not
work.
Power light is on but no mist.
The mist has a strange odour.
Power light is on, but the
machine doesn't work.
The volume of spray mist is too
low.
Abnormal noise
Possible reasons
Humidifier not plugged into the
power outlet.
No water in water tank.
A new machine.
It either has dirty water or the water
has been stagnant too long.
Too much water in the water basin.
Too much mineral scale in the water
basin.
Water is too dirty or water was kept too
long in the tank.
Vibration in the water tank because
the water level is too low.
7
Solution
Connect power cord to electrical
outlet and press power button.
Fill water tank with water.
Remove the water tank, unscrew
the lid and let it air out in a cool
area for 12 hours.
Clean the water tank and refill
with clean water.
Remove the water tank. Take a
small cup and remove some of
the water from the machine's
water basin. Reinsert the water
tank and make sure that it sits
properly.
Clean transducer.
Clean the water tank and refill
with clean water.
Fill the water tank.