4. Proper use
The compressor is designed to generate com-
pressed air for compressed-air driven tools which
can be driven with an air volume of up to approx.
270 l/min (e.g. tire infl ator, blow-out pistol and
paint spray gun). Due to the limited air output it is
not possible to use the compressor to drive tools
with very high air consumption (for example or-
bital sanders, rod grinders and hammer screwdri-
vers).
The equipment is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the manufac-
turer will be liable for any damage or injuries of
any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
5. Technical data
Mains connection: .........................230 V ~ 50 Hz
Motor rating kW: ........................................ 1.8 kW
Operating mode: ................................................ S1
Compressor speed min
-1
: .............................. 2850
Operating pressure bar: .............................. max. 8
Pressure vessel capacity (in liters): ..................... 24
Theoretical intake capacity (l/min): . approx. 270
Sound power level L
in dB: ............................. 94
WA
K
uncertainty: ...............................................4 dB
WA
Protection type: ................................................IP20
Weight of the unit in kg: ...................................... 26
Oil (15W 40): ..................................................0.3 l
Anleitung_4010361_LB2.indb 50
Anleitung_4010361_LB2.indb 50
GB
6. Before starting the
equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
•
Check the equipment for damage which may
have occurred in transit. Report any damage
immediately to the transport company which
was used to deliver the compressor.
•
Install the compressor near the point of con-
sumption.
•
Avoid long air lines and supply lines (extensi-
on cables).
•
Make sure that the intake air is dry and dust-
free.
•
Do not install the compressor in a damp or
wet room.
•
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5 °C to 40 °C). There must
be no dust, acids, vapors, explosive gases or
inflammable gases in the room.
•
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor in
areas where work is conducted with sprayed
water.
•
The oil level in the compressor pump has to
be checked before putting the equipment into
operation (see 9.4).