Indirect measurement (with 2 measuring points)
Partial measurements between two points on an area can-
not be determined by an individual measurement.
• Push the
ment mode
• Target the two points between which you want to calculate
the distance and conduct two individual measurements
(as described in b.)). Internally, the distance between the
two points will be calculated by trigonometry (Pythagoras:
a
+ b
= c
2
2
2
Make sure to measure the point that is farther
away first. If you measure the shorter distance
first, an error message (Err) will appear in the
display.
For correct calculation, the second distance must
be orthogonal on the edge to be calculated.
For a precise measurement, rotate the laser me-
ter at the current point after the first measurement
and do not move it.
Indirect measurement (with 3 measuring points)
If you cannot measure from the position at which one edge
is orthogonal on the edge to be calculated, three distances
must be measured.
• Position yourself within the projected measuring section
for the measurement.
• Push the button
Start the measurement at one end point of the section to
be measured.
56
(3) button once to switch to indirect measure-
.
).
(3) twice until the
icon flashes.