PRESSURE GAUGE
There are 1 or 2 gauges on this type of compressor, one shows pressure in tank and another one
(if there are 2 gauges) shows outlet's pressure after regulator.
MAINTENANCE
▲ WARNING! Disconnect power source then release all pressure from the system
before attempting to install, service, relocate or perform any maintenance.
Check compressor often for any visible problems and follow maintenance
procedures each time compressor is used.
1. Pull ring on safety valve and allow it to snap back to normal position.
▲ WARNING! Safety valve must be replaced if it cannot be actuated or it leaks air after ring is
released.
2. Turn compressor off and release pressure from system. Drain moisture from tank by opening
drain cock underneath tank.
3. Clean dust and dirt from motor, tank, and airlines and pump cooling fins while compressor
is still OFF.
IMPORTANT: Locate unit as far from spraying area, as hose will allow preventing overspray
from clogging filter.
LUBRICATION
SAE30-olie wordt aanbevolen te gebruiken. Houd het oliepeil in de rode cyclus van olieglas.
THERMAL OVERLOAD PROTECTOR
▲ CAUTION! This compressor is equipped with an automatic reset thermal overload protector,
which will shut off motor if it becomes overheated.
If thermal overload protector shuts motor OFF frequently, look for the following causes.
1. Low voltage.
2. Clogged air filter.
3. Lack of proper ventilation.
▲ CAUTION! If the thermal overload protector is actuated, the motor must be allowed to cool down
before start-up is possible. The motor will automatically restart without warning if left plugged into
electrical outlet and unit is turned on.
STORAGE
1. When not in use, store hose and compressor in a cool dry place.
2. Exhaust water from tank.
3. Disconnect hose and hang it on top of compressor, to avoid damage.