2. If repair or replacement of power cord or plug is necessary, do not connect grounding wire to
either flat blade terminal. The wire with insulation having an external surface that is green (with
or without yellow stripes) is the grounding wire.
▲ WARNING! Never connect green (or green and yellow) wire to a live terminal.
3. Check with a qualified electrician or service man if grounding instructions not completely
understood or in doubt as to whether product is properly grounded. Never modify the plug
receptacle privately; if there are not fitting outlet, make proper outlet installed by a qualified
electrician.
▲ WARNING!
1. Local electrical wiring codes differ from area to area. Source wiring, plug and protector must
be rated for at least the amperage and voltage indicated on motor nameplate, and meet
all electrical codes for this minimum,
2. Use a slow blow fuse or a circuit breaker.
▲ CAUTION! Overheating, short circuiting and fire damage will result from inadequate wiring,
etc.
NOTE: 230 volt, 5 amp units can be operated on a 230volt circuit under the following conditions:
a. No other electrical appliances or lights are connected to the same branch circuit.
b. Voltage supply is normal.
c. Circuit is equipped with a 5 amp circuit breaker or a 15 amp slow blow fuse.
3. If these conditions cannot be met or if disconnection of current protection device occurs,
it may be necessary to operate compressor from a 230 volt, 5 amp circuits.
OPERATION
Pressure Switch
Auto/Off Switch-In the "AUTO" position, the compressor shuts off automatically when tank pressure
reaches the maximum preset pressure (0.8Mpa) and runs automatically when tank pressure
reaches the minimum preset pressure (about 0.6Mpa). In the "OFF" position, the compressor will not
operate. This switch should be in the "OFF" position when connecting or disconnecting the power
cord from the electrical outlet or when changing air tools.
Regulator
The regulator use to adjust pressure of outlet to fitting air-power tools.
Safety Valve
It release compressed air automatically when pressure in tank exceeds allowing pressure.
Discharge Pipe
Discharge pipe connects pump head and check valve. It is hot when compressor is running. To
avoid grievous burn, never touch discharge Pipe.
Check Valve
Check valve is a one-way valve allowing compressed air go ahead to the tank, but prevents com-
pressed air in tank back to pump.
Handle and wheels
Designed to move the compressor easily.
▲WARNING! Never use the handle on wheeled units to lift the unit completely off the ground.
Drain Valve
This valve locate at bottom of the tank. used to exhaust water from the tank.
▲
Make sure gauge pressure of tank is below 1 Bar, open the drain valve to exhaust water from tank,
close it tightly. This action should be done every week.
ater from the tank.
gauge
is
the
aust
close
tion
e every