Maintenance and disposal
Replacing the main filter
Every 3000 hours of operation, the 'FILTER' icon will light up and remain lightened, which means that the main
filter (HEPA-13 & activated carbon compound filter) needs to be replaced on both sides. The filter may need to
be replaced in shorter intervals when there is a higher level of dirt in the air as usual.
Dirty filters inhibit the performance of the device. Errors that arise when filters needs to be replaced are
described in chapter Troubleshooting.
1. Switch off and unplug the device from the socket.
Do not touch the plug or the device with damp or wet hands. Otherwise, there is a threat of electric
shock.
Wear gloves and a mask! Otherwise, there is a risk of exposure to contamination, viruses,
bacteria and similar potential hazards.
2. Open the two side plates as described in the chapter Installation.
3. Now carefully extract the filters.
HEPA-13 & activated carbon compound filter
4. Put the replacement filters into the device. Please ensure that the tab side (side with strip) is facing you.
5. Again, complete the respective steps described in the chapter Installation in order to close the side plates
properly.
6. Put the used filters into the remaining bag of the new filters, seal the bags and immediately dispose of them
in your domestic waste. If you notice that any of the parts on or in the device not listed here are missing or
damaged, please contact your local retailer or manufacturer.
7. Then connect the device to power supply, switch it on and press the 'FILTER' button on the control panel
for 3 seconds in order to confirm replacement of the filters and to reset the counter.

Storage

The following storage conditions must be ensured when the device is not in use:
-
Take the battery out of the remote control and store the batteries separately from the remote control.
-
Unplug the device before storing it.
-
Clean the air purifier and particle sensor as explained in the chapter Cleaning. Let all parts dry thoroughly
before moving to the next step.
-
Store the device in a cool and dry place and protect it from both heat and frost.
-
Cover the device with a cover or cloth. Ensure that the device is not connected to a plug socket before
covering it.
-
Before using the device again, check the condition of the power cable. If in doubt, contact customer
services about the condition of the cable.

Disposal (Life-Cycle Service)

As with other electrical and electronic devices, this device must not be disposed of in domestic waste
due to the symbol showing a crossed-out waste bin.
Here at greentec, we want to promote the reuse of recyclable materials. As part of our Life-Cycle Service,
we check the recycling options of old materials in our production chain. Please visit our website at
www.greentec.ag for more information about options and locations for returns.
Help us to improve the recycling of old devices and to avoid negative consequences for the environment and
human health by disposing of your device properly at the end of its lifespan or returning it to us!